Home » Product List » Online ups » Online UPS 6-20KVA
Product Details
Online UPS 6-20KVA
| Model NO.: | BS |
|---|---|
| Trademark: | Srups |
| Origin: | China |
| Phase: | Single Phase |
| Type: | On-line |
Product Description
ONLINE UPS
True online double conversion technology
Wide input voltage range
Zero transfer time
Protection against all types of power problems
No add-on CNTL unit required for parallel connection
Low initial investment and flexible for future expansion
Highest reliability and maximum performance for power sharing and redundancy
Smart RS232 and Intelligent slot interface
Sealed lead-acid, maintenance free battery
IGBT technology
Overload and short circuit protection
LCD / LED status display
N + X parallel connection
Cold start
Intelligent slot for SNMP adaptor(optional)
| Model | BS 6K/6KS | BS 10K/10KS | |
| Rated Power | VA/W | 6kVA/4.2kW | 10kVA/7kW |
| Input | Nominal Voltage | 110VAC/220VAC | |
| Voltage Range | 80-144VAC/176 ~ 276VAC | ||
| Power Factor | 0.98 | ||
| Connection | Hardwired | ||
| Output | Voltage | 110VAC/220VAC ± 1% | |
| Frequency | 60HZ/50Hz ± 0.2Hz (Line mode) 60HZ/50Hz ± 0.2Hz ( Battery mode) | ||
| Waveform | Sine Wave | ||
| Power factor | 0.7 | ||
| Voltage Distortion | 2% under linear load | ||
| Overload Capability | 105% ~ 130% for 10 min., ³ 130% for 1 min. | ||
| Current Crest Ratio | 3:1 max. | ||
| Battery | Type | Sealed, Maintenance free, Lead-Acid | |
| Back-up time (full load) | 5 min | 7 min | |
| Recharge time | 8 hrs to 90% of capacity after full load discharge | ||
| Transfer time | 0 ms | ||
| Maintenance Bypass Switch | Yes | ||
| LED/LCD indicators | Status | Load level/Battery level, Battery , Utility power, Inverter, Bypass, Overload, Fault | |
| Audible alarm | Bypass | Alarm beeps every two minutes | |
| Battery discharge | Alarm beeps every four seconds, every second if battery low | ||
| Overload | Alarm beeps two for every second | ||
| Fault | Alarm beeps continuously | ||
| Acoustic noise | At 1 meter distance | £ 55 dBA | |
| Communications | DB-9 Port | RS232 serial interface | |
| Intelligent Slot | Options: WebPower, AS400 or WinPower CMC | ||
| Environmental | Operating temperature | 0 ~ 40 ° C | |
| Operating humidity | 20% ~ 90% non-condensing | ||
| Weight | Net (kg) | 90/35 | 93/38 |
| Dimensions | W x D x H (mm) | 260*570*717 | |
| Model | BS 15KS | BS 20KS | ||
| Rated Power | VA/W | 15kVA/10.5kW | 20kVA/14kW | |
| Input | Voltage Range | 304~478vac | ||
| Phase | 3 phase (4 wires plus ground) | |||
| Power Factor | 0.95 | |||
| Connection | Ha rdwired | |||
| Output | Voltage | 220VAC ±1%, Single phase | ||
| Frequency | 60HZ/50Hz ± 0.2Hz (Line mode) 60HZ/50Hz ± 0.2Hz ( Battery mode) | |||
| Waveform | Pure Sine Wave | |||
| Power factor | 0.7 | |||
| Voltage Distortion | £ 2% under linear load | |||
| Overload Capability | 105% ~ 130% for 10 min., ³130% for 1 min. | |||
| Current Crest Ratio | 3:1 max. | |||
| Battery | Type | Sealed, Maintenance free, Lead-Acid | ||
| Back-up time (full load) | Depends on the capacity of the external battery capacity | |||
| Transfer time | 0 ms | |||
| Maintenance Bypass Switch | Yes | |||
| LED/LCD indicators | Status | Load level/Battery level, Battery , Utility power, Inverter, Bypass, Overload, Fault | ||
| Audible alarm | Bypass | Alarm beeps every two minutes | ||
| Battery discharge | Alarm beeps every four seconds, every second if battery low | |||
| Overload | Alarm beeps two for every second | |||
| Fault | Alarm beeps continuously | |||
| Acoustic noise | At 1 meter distance | £ 55 dBA | £ 60 dBA | |
| Communications | DB-9 Port | RS232 serial interface | ||
| Intelligent Slot | Options: WebPower, As400 or WinPower CMC | |||
| Parallel Port | up to three units in parallel for power redundancy and load sharing | |||
| Environmental | Operating temperature | 0 ~ 40°C | ||
| Operating humidity | 20% ~ 90% non-condensing | |||
| Weight | Net (kg) | 55 | 55 | |
| Dimensions | W x D x H (mm) | 260*570*717 | ||
Inquiry Basket (